Genosorb Absorption Liquids

Polyethylene glycol dialkyl ethers have proved very successful in practice for scrubbing waste air and waste gas streams containing a variety of organic substances - mostly solvents and acid gases.

Clariant has developed the Genosorb® range of absorption liquids as tailor made solution for many specific waste gas problems. Genosorb absorption liquids have a low vapor pressure and low viscosity

A waste gas stream containing VOCs and / or acid gases is passed through a packed tower. The removal of VOCs is accomplished with a direct contact between the upward gas and the downward Genosorb absorption liquid. This rich Genosorb solution is then passed downward through a packed stripping tower. The VOCs are removed from Genosorb by stripping with steam or air, typically at temperatures between 70°C and 130°C. The resulting lean Genosorb solution is then passed back to the absorber column.

Acid Gas Removal (AGR) - The Selexol® Process

Desulfurization of Flue Gas - The Solinox® Process

VOC Abatement

Clariant in the Laboratory

Product Range

Product
CompositionApplication
Genosorb 1753 Polyglycol dimethyl etherSelexol process, acid gas removal. Absorption of H2S, mercaptans, CO2, CS2 and COS (carbon oxysulfide)
Genosorb 1900 Polyglycol dimethyl ether, stabilizedSolinox process, absorption of SO2 / SO3 from flue gas
Genosorb 300 Polyglycol dimethyl ether, stabilizedAlcohols, aldehydes, ketones, CHCs,
Genosorb 1843 Polyglycol dibutyl ether, stabilizedAromatics, hydrocarbons, FHCs, CFCHs



Solinox® is a trademark of Linde AG
Selexol® is a trademark of Dow Chemical